> ## Content Index
> Fetch the complete content index at: https://www.healthdatacon.io/llms.txt
> Use this file to discover other available public pages before exploring further.

# Top 10 Health Technology Hazards for 2014
- URL: https://www.healthdatacon.io/articles/top-10-health-technology-hazards-for-2014/
- Published: 2013-11-05T14:57:40.000Z
- Updated: 2026-11-10T10:54:47.000Z
- Description: 
- Author: HDM Staff
- Tags: Health IT

The Top 10 list of health technology hazards, developed each year by ECRI Institutes Health Devices Group, highlights the technology safety topics the not-for-profit organization believes warrant particular attention for the coming year.

  
## 1\. Alarm Hazards

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbiulelag1v1t28m1p2rbsa6.jpg)

In an April 2013 Sentinel Event Alert, the Joint Commission cited 98 alarm-related events over a three-and-a-half-year period, with 80 of those events resulting in death and 13 in permanent loss of function. Issues include:  
  
\* Caregivers can become overwhelmed, unable to respond to all alarms or to distinguish among simultaneously sounding alarms.  
  
\* They can become distracted, with alarms diverting their attention from other important patient care activities.  
  
*They can become desensitized, possibly missing an important alarm because too many previous alarms proved to be insigniﬁcant.*  
  
  
## 2\. Infusion Pump Medication Errors

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj0he3371s2v5kj2nitcr7.jpg)

Infusion pumps represent a large technology management burden: A hospital may have hundreds or even thousands of these devices in its inventory, and device failuresor failures to use the devices properlyare not uncommon and can cause signiﬁcant patient harm.  
  
Patients can be highly sensitive to the amount of medication or ﬂuid they receive from infusion pumps, and some medications are life-sustainingor life-threatening if administered incorrectly.  

  
## 3\. CT Radiation Exposures in Pediatric Patients

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj2du1r281gs2dm71tge1gs18.jpg)

Computed tomography (CT) systems have proven to be a valuable tool for diagnosing serious injuries and illnesses. However, this diagnostic imaging technology is not without riskespecially to pediatric patients, who are inherently more sensitive to the effects of ionizing radiation than are adults.  
  
While the risk has always been hard to quantify, newly published empirical studies add to the evidence that exposure to ionizing radiation from diagnostic imaging at a young age can increase a persons risk of developing cancer later in life.  

  
## 4\. Data Integrity Failures in EHRs and other HIT Systems

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj3s7sm510jm1nnv1bmb7aa9.jpg)

Reports illustrate myriad ways that the integrity of the data in an EHR or other health IT system can be compromised. Contributing factors include:  
  
  
patient/data association errorsthat is, one patients data from a medical device or system mistakenly being associated with another patients record  
  
  
\* missing data or delayed data delivery  
  
  
\* clock synchronization errors  
  
\* inappropriate use of default values  
  
  
\* copying and pasting of older information into a new report  
  
  
## 5\. Occupational Radiation Hazards in Hybrid ORs

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj5je1gd51f4214591i4prvaa.jpg)

The implementation of hybrid ORs is a growing trend in healthcare facilities. These operating suites bring advanced imaging capabilities into the surgical environment via built-in, full-scale angiography systems.  
  
However, as these angiography systems are introduced into the OR, so too are the radiation exposure risks. Patient exposure hazards are of course a concern. But perhaps less obvious are the risks to OR staff. Personnel in radiology departments and catheterization labs are generally well versed in the occupational risks.  
  
Outside those environments, knowledge of the risks and the experience in executing precautions may be lacking.

  
## 6\. Inadequate Reprocessing of Endoscopes and Surgical Instruments

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj7j6nd21k8t58pdm41e40b.jpg)

When reprocessing is not performed properly, patient cross-contamination is possible, potentially leading to the transmission of infectious agents and the spread of diseases such as hepatitis C, HIV, and tuberculosis.  
  
Because ﬂexible endoscopes are complex devices with narrow, hard-to-clean channels, they can be particularly challenging to decontaminate. However, endoscopes are not the only devices subject to reprocessing failures.  

  
## 7\. Neglecting Change Management for Networked Devices and Systems

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbj9761o621v5buo8s51hegc.jpg)

ECRI Institute is aware of incidents in which planned and proactive changes to one device or system have adversely affected other networked medical devices and systems. For example:  
  
  
\* A facility-wide PC operating system upgrade caused the loss of remote-display capability for a hospitals fetal monitoring devices.  
  
\* Moving a facilitys obstetrical data management system server off-site led to problems displaying fetal monitor data at the nurses station.  
  
  
\* An EHR software upgrade resulted in changes to certain radiology reports, causing ﬁelds for the date and time of the study to drop from the legal record.  

  
## 8\. Risks to Pediatric Patients from Adult Technologies

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbjb1u142ss471ge17631v63d.jpg)

The care of pediatric patients can be compromised, for example, when applying adult healthcare technologies such as:  
  
\* Using adult radiological scanning techniques on pediatric patients can expose children to an unnecessarily large adult dose.  
  
\* A healthcare facilitys EHR may not be conﬁgured to optimally support the care of children. For example, the system may not facilitate the recording and review of important pediatric-speciﬁc data, such as vaccinations.  
  
\* Medication dosing errors can be particularly harmful to children because of the patients small size.  

  
## 9\. Robotic Surgery Complications Due to Insufficient Training

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbjcsftqp1jgq19e6vjd1lmee.jpg)

The past year has seen a rise in the number of media reports that are critical of robot-assisted surgery. Some of the reports, which describe complications that individual patients have experienced, suggest that robotic systems are being used for a greater number of cases or for additional kinds of procedures without adequate consideration of the surgical teams proﬁciency in using the system for the procedures performed.

  
## 10\. Retained Devices and Unretrieved Fragments

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbjf1u19ek1jp0e3u35544lf.jpg)

\* In the last four years alone, ECRI Institutes Accident and Forensic Investigation Group has investigated nine retained surgical item (RSI) incidents.  
  
\* A 2012 analysis of the Pennsylvania Patient Safety Reporting System data- base showed that healthcare facilities in the commonwealth reported 452 events involving RSIs in 2011one-third of those events reportedly caused patient harm.  
  
\* In October 2013, the Joint Commission issued a Sentinel Event Alert on the unintended retention of foreign objects, noting that 772 such incidents were reported to its Sentinel Event Database from 2005 to 2012, including 16 that resulted in death.  

  
## About ECRI

![](https://hdmpublishing.wpengine.com/wp-content/uploads/2015/11/p188kbjh351b1249q11sli8brrsg.jpg)

For 45 years, ECRI Institute, a nonprofit organization, has been dedicated to bringing the discipline of applied scientific research to discover which medical procedures, devices, drugs, and processes are best.  
  
The organization is designated an Evidence-Based Practice Center by the U.S. Agency for Healthcare Research and Quality and listed as a federal Patient Safety Organization by the U.S. Department of Health and Human Services.  
  
ECRIs Web site is at [www.ecri.org](https://www.ecri.org/?ref=healthdatacon.io)